00How hydrovac works
844-642-8227
NG Companies · Field guide

How hydrovac works

Pressurized water cuts the soil. A vacuum lifts it away. Nothing hard ever touches the pipe. Scroll down and we'll take the machine apart, one layer at a time.

11 chapters~8 min to scroll6 min of narration
Start digging
01

The problem underground

Buried utilities sit inches apart, and a bucket can't feel them.

A crowded maze

Under almost every street sit gas lines, fiber, water mains, power cables and sewers, often stacked within a few feet of each other.

Marking paint and flags follow the APWA uniform color code: yellow for gas, orange for communications, blue for water, red for power, green for sewer.

Steel teeth can't tell

A backhoe bucket feels the same resistance from a gas main as from a rock. Hit the wrong one and the result can be an outage, a fire, or worse.

What strikes cost

$83.2Bper year in the U.S.

The Common Ground Alliance's 2025 cost study modeled about 669,000 damages to buried utilities in a single year, counting repairs, lost business and response costs.

Source: Common Ground Alliance, 2025 cost-of-damage study

Stop using teeth

To dig right beside a live line, you need a tool that can't cut a pipe. Swap steel for two things: water and air.

02

The core idea

Two systems run at once: one cuts, one lifts.

Hydro excavation

Hydro excavation, usually called hydrovac or soft digging, is what NG crews do every day. The whole method fits in one sentence: water loosens the ground, and suction carries it away.

1 · Cut

Water turns soil into slurry

A high-pressure jet breaks the soil apart and mixes it into a thick mud called slurry. The water does the digging, so there's no blade and no bucket in the hole.

2 · Lift

Vacuum carries it away

At the same time, a powerful vacuum pulls the slurry up a wide hose and into a sealed debris tank on the truck. The hole stays clear, so the operator can see what they're uncovering.

Nothing hard touches the pipe

The utility is exposed by washing soil away from it, not by scraping it. That's the whole safety case for hydrovac.

03

Anatomy of a hydrovac

Six systems on one chassis. Tap a part on the truck to jump to it.

Water tanks
200–1,200gallons onboard

Tanks along the frame carry the digging water. Capacity sets how long a crew can work before refilling.

High-pressure pump
2,000–3,000psi typical

The pump feeds the hand-held digging wand at high pressure but a modest flow.

Water heater

Hot water on demand

Many trucks carry a diesel-fired heater so crews can cut frozen ground and dense clay. More on that in chapter 7.

Debris tank
5–15cubic yards

The sealed tank at the rear holds everything the hose picks up, until it's dumped at an approved site.

Vacuum blower

The heart of the machine

The blower pulls air out of the debris tank. That pressure drop is what powers the suction at the end of the hose.

Hydraulic boom
20+feet of reach

The boom swings the heavy suction hose over the hole, so the truck can stay parked clear of the work.

04

The water side

Cutting power, not volume.

2,000–3,000psi at the pump

That's enough pressure to break up packed soil quickly. For scale, a household tap runs at roughly 40–60 psi.

< 10gallons per minute

Dedicated hydrovac units often run under 10 gpm. The goal is cutting power, not flooding the hole, which also keeps the tank from filling with water.

NSC specification: 4–10 gpm for hydro excavation rigs

Rotating beats straight

A straight tip fires one concentrated needle of water. A rotating, or oscillating, nozzle sweeps the jet into a cone, so the energy spreads out. It's the nozzle preferred for exposing utilities.

The rules are simple

  • Keep the tip moving.
  • Hold it 6–8 inches from any utility.
  • Never jab the nozzle into the ground.

Done right, the spray breaks the soil apart while keeping concentrated force off the pipe.

Ditch Witch vacuum-excavation best practices; GTI Vacuum Excavation Best Practice & Guideline
05

The vacuum side

The blower removes air. The atmosphere does the pushing.

Pull the air out

The blower draws air out of the sealed debris tank, dropping its pressure well below the atmosphere outside.

Let the atmosphere push

Outside air rushes toward the low pressure through the only opening: the end of the hose. That fast-moving air carries the slurry with it.

Airflow
2,500–6,000cubic feet per minute

CFM measures how much air moves. More airflow means material moves faster up the hose.

Vacuum depth
27inches of mercury ≈ 90% of a perfect vacuum

Inches of mercury measure how hard the system pulls. A perfect vacuum at sea level is about 29.92 inHg.

Fan or positive displacement?

Fan systems move lots of air but top out around 16 inHg, so they fade on deep holes and long hose runs. Positive displacement blowers reach roughly 15–27 inHg and keep pulling.

Illustrative trend, not measured data for any specific truck.

06

Inside the debris tank

A big, slow room for air, and a chain of guards in front of the blower.

Air slows, debris drops

The fast air stream from the hose suddenly enters a big open tank and slows down. Rock, soil and water can't stay airborne, so they fall to the floor.

Guard 1

Float-ball shutoff

If the tank overfills, rising liquid lifts a float ball that seals the outlet and stops flow to the blower.

Guards 2 and 3

Secondary shutoff, then filters

A backup trap catches carry-over, and filters or cyclones strip out fine dust.

Chandler VAC: primary and secondary shutoffs and final filters
Blower and silencer

Only clean air reaches the blower

What's left is clean air. It passes through the blower and out through a silencer.

Dump the load

When the tank is full, the rear door opens and the body tilts to empty it at an approved disposal or decant site.

07

Hot water, frozen ground

Heat makes hydrovac a year-round tool.

~175°Fheater output

A large onboard heater can deliver very hot water. One commercial unit is rated at 420,000 BTU, about 175°F at 5 gpm.

Dig Different: hydrovac water heater specifications
140–180°Fat the nozzle for frozen ground

That's how hydrovac keeps digging through a Denver or Boise winter, cutting through frost that would stop a shovel.

Hydrovac News cold-weather guide
115°Fguideline cap near facilities

Near buried lines, crews dial temperature and pressure back down. One gas-industry guideline caps water at 115°F and 2,500 psi around facilities.

GTI Vacuum Excavation Best Practice & Guideline (2012)
08

Where hydrovac earns its keep

From test holes to tree roots.

Potholing · Daylighting

See the line before you bore

The most common job is a small test hole that shows a utility's exact depth and position before anyone drills or trenches nearby.

811 marks public lines, not private ones

Calling 811 gets public utilities marked. Private lines, like power to a parking-lot light or a building's own water service, often go unmarked.

NG + Safe Site

Locate first, then dig

NG pairs hydrovac with private utility locating through its partner, Safe Site. Ground-penetrating radar and locators find the unmarked lines, then the hydrovac exposes them.

Beyond potholing

  • Slot trenches for cable and conduit
  • Pole and pile holes
  • Valve box cleanouts
  • Digging around tree roots

Hydro or air excavation?

FactorHydro excavationAir excavation
SpeedGenerally fasterSlower
Clay and frozen groundHandles well, especially with hot waterStruggles
SpoilWet slurry, hauled to a disposal siteDry soil, reusable as backfill
Water supplyRequiredNot needed
Source: GapVax, hydro excavation vs. air excavation
09

Disposal and safety

Wet spoil and a powerful jet both need a plan.

~60%water in raw slurry

Slurry goes to approved disposal or dewatering sites, where solids are separated from water, tested, then landfilled or recycled. It never goes down a storm drain.

Hydrovac News: slurry handling and disposal guide

Good process still comes first

  • Call 811 before digging
  • Chock the wheels
  • Work in crews of at least two
  • Wear eye, face and hearing protection

Water at thousands of psi can cause injection injuries. Never point the wand at anyone.

National Safety Council: hydro and pneumatic vacuum excavation specification
10

Why NG Companies

National reach. Local crews.

Damage prevention

Six locations, nationwide work

NG crews work from Nashville, Dallas–Fort Worth, Tampa, Charlotte, Boise and Denver, and travel to projects across the country.

One call, the full subsurface toolkit

Hydrovac is one of five NG services, alongside utility locating, video pipe inspection, hydro jetting and trenchless pipe repair.

Real projects

NG has handled potholing, coring and full excavation for a downtown Kansas City water main replacement, and complex excavation for Tampa International Airport's new terminal.

Same commitment, any size

Large contractor or small, NG brings the same commitment and the same grit, across industrial, education, residential, manufacturing, commercial, public infrastructure, healthcare, energy and heavy civil work.

11

The whole machine in four steps

The result is a hole dug exactly where you need it, with the buried lines around it still intact.

1

Water cuts

2,000–3,000 psi through a moving, rotating nozzle loosens soil into slurry.

2

Air lifts

Low pressure in the tank lets the atmosphere push slurry up the hose.

3

The tank separates

Air slows in the big tank and the heavy material drops out.

4

Guards protect the blower

Shutoffs and filters make sure only clean air reaches it.

Ready to solve what's below?

Schedule a hydrovac crew

844-642-8227 Call
Nashville · Dallas–Fort Worth · Tampa · Charlotte · Boise · Denver
Dig with confidence.
Sources and notes
  1. Common Ground Alliance cost-of-damage study: $83.2B per year, about 669,000 modeled damages.
  2. GTI Vacuum Excavation Best Practice & Guideline (2012): nozzle types, 8 in. standoff, 115°F and 2,500 psi limits.
  3. National Safety Council specification: pressure, flow, CFM, inHg, PPE and crew requirements.
  4. Ditch Witch: five best practices: rotating nozzle, 6–8 in., keep moving, never dig with the nozzle.
  5. Hydrovac News: inches of mercury, blower types, cold-weather digging and slurry disposal.
  6. Haaker: fan vs. positive displacement blowers.
  7. Chandler VAC: primary and secondary shutoffs and filters.
  8. TRUVAC and GapVax: tank capacities, boom reach, hydro vs. air.
  9. Dig Different: hydrovac water heater specifications.
  10. NG Companies: services, locations, markets and project summaries.
  11. Figures are typical industry ranges, not guarantees for a specific truck or site. Always follow equipment manuals, local regulations and utility-owner requirements. Narration is an AI voice (ElevenLabs). Illustrations are schematic.